| Product reference |
A-TL44A
|
A-TL44B
|
A-TL45A
|
A-TL45B
|
| Product description |
Safety bay light, compressed air pwrd
|
Safety flood light, compressed air pwrd
|
| Code |
ATEX Industrial |
II 2 GD II T4 (Tamb = 55°C) T135°C
|
| ATEX Mining |
|
I M2
|
|
I M2
|
| FM |
Class 1 Div 1 Groups A, B, C, D. T4 Ta = 55°C
|
| Equipment category |
2 GD
|
| |
M2
|
|
M2
|
| Apparatus standards |
EN1127:1998
|
| Type of protection |
Technical File
|
| Area of class (gases) |
Zones 1 and 2, Gas Groups IIA, IIB, IIC
|
| temp. class (gases) |
T4
|
| Area of class (dusts) |
Zones 21 and 22
|
| Max surface temp. (dusts) |
T135°C
|
| Ambient temperature |
-20°C to +40°C
|
| Certificate |
SIRA02ATEX5099X
|
| Enclosure |
Aluminium
|
Brass
|
Aluminium
|
Brass
|
| Lens |
Lens Ball glass/plastic dome
|
Toughened glass (15mm)
|
| Beam type |
All-around 360°C illumination
|
Flood (as standard) or spot to order
|
| Light source: |
Pt. no. |
A-129 (as standard)/A-159 (alternative)
|
| Type |
Halogen filled filament bulb
|
| Volts |
24v
|
| Watts |
250w
|
| Output |
6000 lm/9000 lm
|
| Life |
2000 hrs/200 hrs
|
| Power source: |
Type |
Compressed air driven turbo-alternator
|
| Air pressure |
5.0-8.0 bar
|
| Consumption |
0.75m3/min
|
| Ingress protection |
Once pressurised, may be used underwater
|
| Weight |
5.5kg
|
9.4kg
|
7.1kg
|
13.5kg
|
| Special certification conditions |
A clean dry air supply must be used
Supply hose must be anti-static
Lamps used in explosive dust atmospheres must have a remote exhaust hose to the safe area
|