Leadlamp Flameproof - Specifications

 

Product reference LL-12
LL-24
LL-42
Product designation KHLE 70 EN
Product description
High power halogen floodlight leadlamp
Code
II 2 G EEx d e IIC T3/T4
Equipment Category
2G
Apparatus standards EN50014, EN50018, EN50019
Type of protection "d" flameproof, "e" increased safety
Area of classification (Gases) Zones 1 and 2, Gas Groups IIA, IIB, IIC
Temp. classification T4
T3
T3
Ambient temperature -20°C to +40°C
Certificate DMT 03 ATEX E279
Enclosure Light alloy, high impact plastic, oil resistant rubber
Lens Toughened glass
Light source:   Pt. no.
LL-230
LL-232
LL-234
Type Halogen filled filament bulb
Volts
12v
24v
42v
Watts
55w
70w
65w
Beam 100° wide angle flood
Life Up to 1000hrs
Power source: Insulation Class lll
Voltage
12 Vac/dc
24 Vac/dc
42 Vac/dc
Ingress protection IP54 minimum
Weight   2.5kg (excluding cable)
 
Complies with ATEX Directive. 94/9/EC
High output halogen light, up to 70 watts
Lightweight alloy construction for single handed portability
Zone 1 & 2, Gas group IIC T3/T4 certified b
Designed for quick and easy re-lamping and maintenance
12, 24 or 42 Volts models available
Integral operation switch
Oil resistant rubber guard for drop and impact protection
Ideal for cleaning, grit blasting and painting operations


 
  Brochure Back