| Product reference |
LL-12 |
LL-24 |
LL-42 |
| Product designation |
KHLE 70 EN |
| Product description |
High power halogen floodlight leadlamp |
| Code |
II 2 G EEx d e IIC T3/T4 |
| Equipment Category |
2G |
| Apparatus standards |
EN50014, EN50018, EN50019 |
| Type of protection |
"d" flameproof, "e" increased safety |
| Area of classification (Gases) |
Zones 1 and 2, Gas Groups IIA, IIB, IIC |
| Temp. classification |
T4 |
T3 |
T3 |
| Ambient temperature |
-20°C to +40°C |
| Certificate |
DMT 03 ATEX E279 |
| Enclosure |
Light alloy, high impact plastic, oil resistant rubber |
| Lens |
Toughened glass |
| Light source: |
Pt. no. |
LL-230 |
LL-232 |
LL-234 |
| Type |
Halogen filled filament bulb |
| Volts |
12v |
24v |
42v |
| Watts |
55w |
70w |
65w |
| Beam |
100° wide angle flood |
| Life |
Up to 1000hrs |
| Power source: |
Insulation |
Class lll |
| Voltage |
12 Vac/dc |
24 Vac/dc |
42 Vac/dc |
| Ingress protection |
IP54 minimum |
| Weight |
2.5kg (excluding cable) |
|
|
 |
Complies with ATEX Directive. 94/9/EC |
 |
High output halogen light, up to 70 watts |
 |
Lightweight alloy construction for single handed portability |
 |
Zone 1 & 2, Gas group IIC T3/T4 certified b |
 |
Designed for quick and easy re-lamping and maintenance |
 |
12, 24 or 42 Volts models available |
 |
Integral operation switch |
 |
Oil resistant rubber guard for drop and impact protection |
 |
Ideal for cleaning, grit blasting and painting operations |

|