| Product reference |
HL-95
|
| Product description |
Primary battery operated safety hazard lamp
|
| Code |
II 1 G EEx ia IIC T4
|
| Apparatus standards |
EN50 014, EN50 020
|
| Type of protection |
"i" intrinsic safety
|
| Area of classification (Gases) |
Zones 0, 1 and 2, Gas Groups IIA, IIB and IIC
|
| Temp. classification |
T4
|
| Ambient temperature |
-20°C to +40°C
|
| Certificate |
BAS 99 ATEX 1044
|
| Enclosure |
Polypropylene with metal lens guard
|
| Lens |
Transparent plastic, colour as light source
|
| Light output |
Output in accordance with requirements for
BS 3143:pt2, Road danger lamps
|
| Light source: |
Type |
Solid state L.E.D.
|
| |
Colour |
Amber as standard, red to order
|
| Power source: |
Pt. no. |
HL-3155X
|
| |
Type |
Air depolarised primary cell battery
|
| Volts |
5.6v
|
| Capacity |
50Ah
|
| Weight |
1.7kg
|
| Dimentions |
L 110 x W 110 x H 140 mm
|
| Light duration |
1500hrs flashing mode, 500hrs static mode
|
| Ingress protection |
IP21
|
| Weight (incl. battery) |
2.9kg
|
|
|
 |
Approved for safe use in Zones 0, 1 or 2 |
 |
Flashing or static output selectable |
 |
Operation in flashing mode up to 2 months |
 |
Daylight cut-out mode selectable |
 |
Ultra-bright L.E.D. light source |
 |
180° bi-directional lens arrangement |
 |
Highlighting obstacles in the hazardous area |
 |
Effective demarcation of hazardous area zones |

|